ASME BPVC標(biāo)準(zhǔn)的無損檢測(cè)內(nèi)容介紹
7月底在上海講ASME Ⅷ-1設(shè)計(jì)培訓(xùn)時(shí),有學(xué)員問工廠想用TOFD代替RT是否可以,有什么依據(jù)等。周末休息,理一下ASME BPVC標(biāo)準(zhǔn)中有關(guān)的無損檢測(cè)的內(nèi)容!
焊縫的無損檢測(cè)分為RT,UT,PT,MT,TOFD等;原材料的檢測(cè)就只用UT了。
RT怕厚不怕薄,UT怕薄不怕厚;MT只能檢測(cè)鐵磁性材料,UT對(duì)奧氏體相焊縫檢測(cè)效果不是很好等常識(shí)性的東西就不做過多介紹了。基本常識(shí)性的內(nèi)容不知道的找國內(nèi)的標(biāo)準(zhǔn)和資料看看。
1)RT部分主要分布在:- UW-2 特殊設(shè)計(jì)和使用要求;- UW-9 縱縫錯(cuò)開排列;- UW-11 規(guī)定和運(yùn)用;- UW-12 焊縫系數(shù);- UW-42 返修和堆焊;
- UW-51 100%RT(100%檢測(cè)時(shí)判定合格的標(biāo)準(zhǔn));- UW-52 RT抽檢(部分檢測(cè)時(shí)判定合格的標(biāo)準(zhǔn))。UW-51和UW-52可以看成是等同于國內(nèi)的Ⅱ級(jí)和Ⅲ級(jí)合格。具體的合格指標(biāo)見標(biāo)準(zhǔn)原文,關(guān)注我信息的人做無損的幾乎沒用就不磨嘰寫合格指標(biāo)了。
UCS-57、UNF-57、UHA-33等條款也有關(guān)于RT的要求。
2)UT的要求:在2019版ASME BPVC Ⅷ-1中不在排斥UT檢測(cè)。在UW-11和UW-12中都直接加入了UT檢測(cè)。主要分布在UW-11,UW-12,UW-53,附錄 12。要求厚度≥6mm,實(shí)際上很多UT操作人員做不了6mm,很多工廠按大于等于8mm執(zhí)行。
3)PT/MT的要求及主要分布:附錄6 MT,附錄8 PT
UW-34 旋壓孔 :當(dāng)旋壓孔用塞焊或焊接封死,完工的焊縫應(yīng)進(jìn)行表面PT/MT檢測(cè)。
UW-42 堆焊:堆焊表面必須要按附錄6或8進(jìn)行MT/PT檢測(cè)
UW-50 氣壓試驗(yàn)容器焊縫的無損檢測(cè):焊縫全長(zhǎng)要進(jìn)行MT/PT檢測(cè)。
A)開孔附近的焊縫。B)所有連接焊縫包括受壓件和非受壓件的連接焊縫只要其角焊縫大于6mm。
UHA-34奧氏體不銹鋼厚度大于19mm及雙相鋼時(shí)對(duì)接及其上的角接焊縫要100%PT檢測(cè)。
UNF-58N06625的2級(jí)及N10665,N10001,鈦,鋯材料制造的容器所有坡口焊縫和角焊縫要進(jìn)行PT檢測(cè)。當(dāng)大部分鎳合金不進(jìn)行100%RT時(shí)的焊縫。
4)TOFD:這個(gè)在code case 2235目前是2235-14,差不多每二年就會(huì)更新一次。大于等于1/2”(13mm)才可以使用。注意TOFD的合格指標(biāo)一定要用code case 2235的表不能和附錄12混用。
TOFD可以代替RT在標(biāo)準(zhǔn)的解釋中,解釋了很多次,摘錄幾條比較典型的問題和回復(fù)見下文。
Interpretation:VIII-1-98-41
Question: Is it permissibleto use the Ultrasonic Time-of-Flight-Diffraction (TOFD) Technique whenimplementing Code Case 2235?
Reply: Yes.
Interpretation:VIII-1-04-95
Question (1): Is it theintent of Code Case 2235-6 (2235-7) that when portions of the vessel meet the requirementsof UW-11(a) for full radiography and portions meet the requirements of CodeCase 2235-6 for using ultrasonic examination in lieu of radiography, the vesselnameplate be stamped with “RT-1”?
Reply (1): Yes, providedthe extent of examination, joint efficiencies, and the Code Case are noted onthe Manufacturer’s Data Report and the nameplate is marked under the CodeSymbol stamp by applying "UT."
Question (2): May a vesselnameplate be stamped “RT-2” per the rules of UG -116 of Section VIII, Division1, when a complete vessel satisfies the requirements of UW-11(a)(5) and whenthe spot radiography requirements of UW-11(a)(5)(b) have been applied but whenultrasonic examination in accordance with the provisions of Code Case 2235-6has been used in lieu of radiography?
Reply (2): Yes, providedthe extent of examination, joint efficiencies, and the Code Case are noted onthe Manufacturer’s Data Report and the nameplate is marked under the CodeSymbol stamp by applying "UT."
Interpretation:VIII-1-07-68
Question (1): Does CodeCase 2235-9 require an ultrasonic examination plan capable of detectingindications transverse as well as parallel to the weld centerline?
Reply (1): Yes.
Question (2): Are theacceptance criteria specified in Tables 1, 2 and 3 of Code Case 2235-9 applicableto indications oriented transverse as well as parallel to the weld centerline?
Reply (2): Yes.
我就不翻譯標(biāo)準(zhǔn)解釋的內(nèi)容了,比我英語差的都沒考上高中。別讓我這個(gè)英語墊底的人鄙視你。
最后再說一下材料的UT,材料的UT檢測(cè)常用的見有以下幾個(gè)標(biāo)準(zhǔn):SA-388,SA-435,SA-577,SA-578,SA-745。
SA-388用于鍛件和棒料(包括直射波和斜射波),環(huán),法蘭和其它中空的鍛件用斜射波合適。平蓋,管板這類鍛件用直射波就可以。合格指標(biāo)要參照其它標(biāo)準(zhǔn)例如鋼板的UT或ASME Ⅷ-2的要求。
SA-745 用于奧氏體不銹鋼鍛件(包括直射波和斜射波)。
SA-435用于板材(直射波)。鎮(zhèn)靜鋼和合金鋼厚度≥12.5mm
SA-577用于板材(斜射波),對(duì)板材來說算是特殊要求。
SA-578用于板材(直射波), 碳鋼和合金鋼厚度≥10mm,復(fù)合板標(biāo)準(zhǔn)SA-263,SA-264,SA-265,ASTM B432,B898,用的就是SA-578。
-
Origin(Pro):學(xué)習(xí)版的窗口限制【數(shù)據(jù)繪圖】 2020-08-07
-
如何卸載Aspen Plus并再重新安裝,這篇文章告訴你! 2020-05-29
-
CAD視口的邊框線看不到也選不中是怎么回事,怎么解決? 2020-06-04
-
教程 | Origin從DSC計(jì)算焓和比熱容 2020-08-31
-
CAD外部參照無法綁定怎么辦? 2020-06-03
-
CAD中如何將布局連帶視口中的內(nèi)容復(fù)制到另一張圖中? 2020-07-03