首頁 > 標準下載>ISO 21501-2-2019 粒徑分布測定--單粒子光相互作用法--第2部分:光散射式液體載體粒子計數(shù)器 Determination of particle size distribution — Single particle light interaction methods — Part 2: Light scattering liquid-borne particle counter免費下載
ISO 21501-2-2019 粒徑分布測定--單粒子光相互作用法--第2部分:光散射式液體載體粒子計數(shù)器 Determination of particle size distribution — Single particle light interaction methods — Part 2: Light scattering liquid-borne particle counter ISO 21501-2-2019 粒徑分布測定--單粒子光相互作用法--第2部分:光散射式液體載體粒子計數(shù)器 Determination of particle size distribution — Single particle light interaction methods — Part 2: Light scattering liquid-borne particle counter

ISO 21501-2-2019 粒徑分布測定--單粒子光相互作用法--第2部分:光散射式液體載體粒子計數(shù)器 Determination of particle size distribution — Single particle light interaction methods — Part 2: Light scattering liquid-borne particle counter

  • 標準類別:
  • 標準大小:
  • 標準編號:ISO 21501-2-2019
  • 標準狀態(tài):現(xiàn)行
  • 更新時間:2023-11-02
  • 下載次數(shù):
標準簡介

This document describes a calibration and verification method for a light scattering liquid-borne 
particle counter (LSLPC), which is used to measure the size and particle number concentration of 
particles suspended in liquid. The light scattering method described in this document is based on single 
particle measurements. The typical size range of particles measured by this method is between 0,1 µm 
and 10 µm in particle size.
The method is applicable to instruments used for the evaluation of the cleanliness of pure water and 
chemicals, as well as the measurement of number and size distribution of particles in various liquids. 
The measured particle size using the LSLPC depends on the refractive index of particles and medium; 
therefore, the measured particle size is equivalent to the calibration particles in pure water.
The following are within the scope of this document:
— size setting error;
— counting efficiency;
— size resolution;
— false count;
— maximum particle number concentration;
— sampling flow rate error;
— sampling time error;
— sampling volume error;
— calibration interval;
— reporting results from test and calibration.nd edition 2019-11 Determination of particle size distribution — Single particle light interaction methods — Part 2: Light scattering liquid-borne particle counter Détermination de la distribution granulométrique — Méthodes d'interaction lumineuse de particules uniques — Partie 2: Compteur de particules en suspension dans un liquide en lumière dispersée Reference number ISO 21501-2:2019(E) ? ISO 2019 ISO 21501-2: