国产aaaa级全身裸体精油片_337p人体粉嫩久久久红粉影视_一区中文字幕在线观看_国产亚洲精品一区二区_欧美裸体男粗大1609_午夜亚洲激情电影av_黄色小说入口_日本精品久久久久中文字幕_少妇思春三a级_亚洲视频自拍偷拍

首頁(yè) > 標(biāo)準(zhǔn)下載>ASTM E2446-2015 計(jì)算機(jī)X光系統(tǒng)分類規(guī)程 Standard Practice For Manufacturing Characterization Of Computed Radiography Systems免費(fèi)下載
ASTM E2446-2015 計(jì)算機(jī)X光系統(tǒng)分類規(guī)程 Standard Practice For Manufacturing Characterization Of Computed Radiography Systems ASTM E2446-2015 計(jì)算機(jī)X光系統(tǒng)分類規(guī)程 Standard Practice For Manufacturing Characterization Of Computed Radiography Systems

ASTM E2446-2015 計(jì)算機(jī)X光系統(tǒng)分類規(guī)程 Standard Practice For Manufacturing Characterization Of Computed Radiography Systems

  • 標(biāo)準(zhǔn)類別:
  • 標(biāo)準(zhǔn)大?。?/li>
  • 標(biāo)準(zhǔn)編號(hào):ASTM E2446-2015
  • 標(biāo)準(zhǔn)狀態(tài):現(xiàn)行
  • 更新時(shí)間:2023-08-27
  • 下載次數(shù):
標(biāo)準(zhǔn)簡(jiǎn)介

1.1 This practice describes the manufacturing characterization of computed radiography (CR) systems, consisting of a particular phosphor imaging plate (IP), scanner, software, and an image display monitor, in combination with specified metal screens for industrial radiography. 1.2 The practice defines system tests to be used to characterize the systems of different suppliers and make them comparable for users. 1.3 This practice is intended for use by manufacturers of CR systems or certification agencies to provide quantitative results of CR system characteristics for nondestructive testing (NDT) user or purchaser consumption. Some of these tests require specialized test phantoms to ensure consistency of results among suppliers or manufacturers. These tests are not intended for users to complete, nor are they intended for long term stability tracking and lifetime measurements. However, they may be used for this purpose, if so desired. 1.4 The CR system performance is described by the basic spatial resolution, contrast, signal and noise parameters, and the equivalent penetrameter sensitivity (EPS). Some of these parameters are used to compare with DDA characterization and film characterization data (see Practice E2597 and Test Method E1815). Note 1: For film system characterization, the signal is represented by the optical density of 2 (above fog and base) and the noise as granularity. The signal-to-noise ratio is normalized by the aperture (similar to the basic spatial resolution) of the system and is part of characterization. This normalization is given by the scanning circular aperture of 100 µm of the micro-photometer, which is defined in Test Method E1815 for film system characterization. 1.5 The measurement of CR systems in this practice is restricted to a selected radiation quality to simplify the procedure. The properties of CR systems will change with radiation energy but not the ranking of CR system perfo

標(biāo)準(zhǔn)截圖
下一條:返回列表
版權(quán):如無(wú)特殊注明,文章轉(zhuǎn)載自網(wǎng)絡(luò),侵權(quán)請(qǐng)聯(lián)系cnmhg168#163.com刪除!文件均為網(wǎng)友上傳,僅供研究和學(xué)習(xí)使用,務(wù)必24小時(shí)內(nèi)刪除。