Study of the energy response of high pressure ionization chamber for high energy gamma-ray
- 期刊名字:中國物理C(英文版)
- 文件大?。?/li>
- 論文作者:HUA Zheng-Dong,XU Xun-Jiang,WA
- 作者單位:Shanghai Institute of Applied Physics,Institute of High Energy Physics
- 更新時間:2022-11-28
- 下載次數(shù):次
The energy response calibration of the commonly used high pressure ionization chamber is very difficult to obtain when the gamma-ray energy is more than 3 MeV.In order to get the calibration of the higher part of the high pressure ionization chamber,we use the Fluka Monte Carlo program to perfclrm the energy response in both the spherical and the cylindrical high pressure ionization chamber which are full of argon gas.The results compared with prior study when the gamma-ray energy is less than 1.25 MeV.Our result of Monte Carlo calculation shows agreement with those obtained by measurement within the uncertainty of the respective methods.The calculation of this study is significant for the high pressure ionization chamber to measure the high energy gamma-ray.
-